Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-ZS5
Brand:fengtu
1.Online ammonia nitrogen analyzer product introduction
The online ammonia nitrogen analyzer is used to monitor the concentration of ammonia in drinking water and surface water. The results of ammonia nitrogen detection can be obtained quickly and accurately.ZS5online ammonia nitrogen analyzer is an instrument that can monitor ammonia nitrogen in water quality online. It integrates water quality ammonia nitrogen sensors and measurement module communication storage, and can quickly and accurately record key parameters in water bodies. At the same time, the instrument supports extended water quality multi-parameter sensors, including but not limited to ammonia nitrogen, ORP, pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of online ammonia nitrogen analyzer
Online multi-parameter water quality detectors are widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical features of online ammonia nitrogen analyzer
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Technical parameters of online ammonia nitrogen analyzer
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V / 1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Online ammonia nitrogen analyzer dimensions
6. Online ammonia nitrogen analyzer sensor configuration (optional)
PH | Measuring principle: electrochemical (salt bridge) Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~14 (PH) Resolution: 0.01 Measurement accuracy: ± 0.1PH ± 0.1℃ Cable length: 5 meters as standard Measuring environment: Temperature 0~50℃ (no freezing), <0.2Mpa Waterproof grade: IP68 Installation method: Immersion installation, NPT3/4 thread |
ORP | Measuring principle: electrochemical (salt bridge) Signal mode: RS485 (MODBUS-RTU) Measuring range: -1500~+1500 (mV) Resolution: 1mV Measurement accuracy: ± 6 mV Cable length: 5 meters as standard Measuring environment: Temperature 0~50℃ (no freezing), <0.2Mpa Waterproof grade: IP68 Installation method: Immersion installation, NPT3/4 thread |
COD | Measuring principle: UV 254 absorption method dual light source measurement Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~200mg/L 0~500mg/ LResolution: 0.1mg/LMeasuring accuracy: ± 5% ±0.3℃ Cable length: 5 meters as standard Measuring environment: temperature 0~50℃ (no freezing), <0.2MpaWaterproof level: IP68Installation method: immersion installation, NPT3/4 threadSelf-cleaning function: with automatic cleaner to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, power consumption 0.7W |
Electrical conductivity EC | Measuring principle: contact electrode method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~5000 us/cm Resolution: 1 us/cm Measuring accuracy: ± 1.5% ±0.1℃ Cable length: 5 meters as standard Measuring environment: Temperature 0~50℃ (no freezing), <0.2Mpa Waterproof level: IP68 Installation method: Immersion installation, NPT3/4 thread |
Dissolved oxygen DO | Measuring principle: fluorescence lifetime method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~20mg/LResolution : 0.01mg/LMeasuring accuracy: ± 2% ±0.3℃ Cable length: 5 meters as standard Measuring environment: Temperature 0~50℃ (no freezing), <0.2MpaWaterproof level: IP68Installation method: Immersion installation, NPT3/4 thread |
Suspended solids SS | Measuring principle: scattered light method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~2000mg/LResolution : 0.1mg/LMeasuring accuracy: ± 5% (depending on sludge homogeneity) Cable length: 5 meters as standard Measuring environment: temperature 0~50℃ (no freezing), <0.2MpaWaterproof level: IP68Installation method: immersion installation, NPT3/4 thread |
TurbidityTU | Measuring principle: scattered light method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0~40NTU 0~1000NTU 0~3000NTU Resolution: 0.1NTU Measuring accuracy: ± 1% ±0.3℃ Cable length: standard 5 meters Measuring environment: temperature 0~50℃ (no freezing), <0.2Mpa Waterproof level: IP68 Installation method: immersion installation, NPT3/4 thread |
Ammonia nitrogen | Measuring principle: ion selective electrode method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0-100mg/l Resolution: 0.01mg/l Measuring accuracy: ±1mg Cable length: 5 meters as standard Measuring environment: Temperature 0~50℃ (no freezing), <0.2Mpa Waterproof level: IP68 Installation method: Immersion installation, NPT3/4 thread |
Chlorophyll | Measuring principle: fluorescence method Signal mode: RS485 (MODBUS-RTU) Measuring range: 0-400ug/LResolution : 0.01ug/LMeasuring accuracy: R2>0.999Cable length: 5 meters as standard Measuring environment: temperature 0~50℃ (no freezing), <0.2MpaWaterproof level: IP68Installation method: immersion installation, NPT3/4 threadSelf-cleaning function: with automatic cleaner to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, power consumption 0.7W |
Fengtu Air quality monitoring station provides accurate data support for air quality monitoring through automation technology. The system is capable of real-time monitoring of a wide range of key pollutants in the atmosphere (e.g. SO2, NO2, CO, O3, TVOC, PM2.5, PM10) as well as meteorological parame...
Radar flowmeter is the use of microwave technology for water level and flow rate detection instrument, it will be mature radar water level meter and radar flow meter measurement technology, mainly used for rivers, reservoir gates, underground waterway pipe network, irrigation channels and other null...
In the absence of instrumentation, the moisture condition of the soil can be quickly assessed by hand feel and is usually categorised into the following four classes:Wet: if water flows out visibly when the soil is squeezed, this indicates high soil moisture.Wet: Soil that leaves wet marks in the ha...
The campus automatic weather station plays a very important role in practice as one of the school's important teaching and research equipment. It is supported by a computer to collect, process and transmit weather data, and to provide teachers and students with queries and applications. It is ma...