Aquaculture Water Quality Monitoring

Aquaculture Water Quality Monitoring

Model:FT-SC07

Brand:fengtu

Aquaculture Water Quality Monitoring can realize water temperature, ph, ammonia nitrogen, residual chlorine, dissolved oxygen, electrical conductivity, turbidity monitoring.
  • Product details
  • Related products
  • Related articles

1. Aquaculture Water Quality Monitoring Product Introduction

Aquaculture Water Quality Monitoring can realize water temperature, ph, ammonia nitrogen, residual chlorine, dissolved oxygen, electrical conductivity, turbidity monitoring.SC07 Online Aquaculture Water Quality Monitoring is an instrument that can monitor water temperature, pH, ammonia nitrogen, residual chlorine, dissolved oxygen, conductivity, and turbidity online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record the key parameters in the water body. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.

2. Aquaculture Water Quality Monitoring Application Areas

Online Aquaculture Water Quality Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:

1. Aquaculture monitoring: used to monitor aquaculture water quality parameters such as ammonia nitrogen, pH, water temperature, etc., in order to optimize the aquaculture environment and improve the production speed and product quality of aquatic products.

2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.

3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.

4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.

5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.

6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.

7. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.

8. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.

3. Technical Features of Aquaculture Water Quality Monitoring

1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.

2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.

3. Scalability: Various sensors can be freely combined.

4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.

5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.

6. Compact structure: can be installed in small places.

7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.

4. Aquaculture Water Quality Monitoring Technical Parameters

Display Output4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight
power supplyDC power supply: DC12V
Power consumptionThe power consumption of the instrument is about 12V/1W
Sound Outputbuzzer
Communication ProtocolStandard RS485 Modbus-RTU protocol and device master/slave transmission channel support
Main MaterialsABS+PC material
Storage temperature-20 to 70°C
Operating temperature-10 to 50°C
Protection levelIP65
size175mm*140mm*49mm(length×width×height)
weightAbout 0.5KG

5. Aquaculture Water Quality Monitoring Sensor Configuration (Optional)

Serial numbernameMeasuring rangeprincipleMeasurement accuracyConfigurationRemark
1temperature0~50℃High-precision digital sensor±0.3℃
2pH0~14 (ph)Electrochemistry (Salt Bridge)± 0.1PH
3ORP-1500mv~1500mvElectrochemistry (Salt Bridge)± 6mv

4Conductivity0~5000uS/cmContact electrode method± 1.5%
5Turbidity0~40NTU (low turbidity)Scattered light method± 1%
Optional
0~1000NTU (medium turbidity)Scattered light method± 1%
0~3000NTU (high turbidity)Scattered light method± 1%
6Dissolved oxygen0~20mg/LFluorescence lifetime method± 2%
7Ammonia nitrogen0~100mg/lIon Selective Electrode Method±1mg
8Suspended Matter0~2000mg/LScattered light method±5% (depending on sludge homogeneity)

9Residual chlorine0~5.00 mg/LIon Selective Electrode Method±5% of reading
10Chloride ion0-3500.0mg/LIon Selective Electrode Method±5%

11Total hardness0~1000.0mg/LIon Selective Electrode Method±10% of reading

12cod0~500mg/LUV254 absorption method±5%
COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W
13Chlorophyll0~400ug/LFluorescence methodR2>0.999