Model:TDS-100
Brand:fengtu
1.Fixed Ultrasonic Flow Meter Product Introduction
Fixed Ultrasonic Flow meter determines the flow rate by sending the ultrasonic signal and calculating the flow rate of the fluid by the time difference of receiving the return signal.Fixed Ultrasonic Flow meter integrates the company's more than ten years of professional production and manufacturing of ultrasonic flow meter technology and experience, using TI's MFP430FG4618 low-power microcontroller, is a high-performance, low-price, good reliability, powerful new ultrasonic flow meter product.
The product has been greatly improved compared with the original ultrasonic flowmeter in terms of measurement accuracy, measurement stability, communication protocol, ease of use, etc. At the same time, it has achieved the non-adjustment of component parameters during the production process, the production process is simpler and more applicable, and the product consistency is better, thus ensuring that each product leaving the factory achieves the best performance.
2. Working Principle of Fixed Ultrasonic Flow Meter
When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in the propagation time. The change in propagation time is proportional to the flow rate of the liquid. At zero flow, the time required for the two sensors to transmit and receive sound waves is exactly the same (the only technology that can actually measure zero flow). When the liquid flows, the sound wave transmission time in the upstream direction is greater than the sound wave transmission time in the downstream direction.
3. Fixed Ultrasonic Flow Meter Product Features
In addition to the general functions of similar products, ultrasonic flow meters also have the following features:
1. The number of sampling times per cycle has been increased to 128 times, and the measurement results are more stable. It can meet the flow measurement needs of most clean water, sewage and various chemical liquids, and greatly reduce the interference of poor detection environment on the measurement results.
2. The use of electrically isolated DC power supply greatly improves the reliability and anti-interference of the host. If there is no power supply on site, users can choose a 15W solar panel with a 24V/30AH lead-acid battery pack, and can achieve continuous power supply for a week on cloudy days.
3. The measuring mainboard is equipped with a standard isolated RF-485 interface, which can support both MODBUS and M-BUS standard protocols, and is fully compatible with the communication protocol of the original ultrasonic flow meter and various flow meter water meter protocols produced by the company.
4. The measurement mainboard is equipped with a serial expansion bus interface, and users can select various function expansion modules for function expansion. The expandable functions include 4-20mA current loop output, frequency signal output, large-capacity data recording, thermal printer, etc.
5. The mainboard has two three-wire PT100 platinum resistance input circuits. When connected to a platinum resistance, it becomes a complete ultrasonic calorimeter. At the same time, the temperature difference sensitivity function is added to prevent the ineffective accumulation of heat during long-term low flow rate or low temperature difference.
6. The mainboard has three analog input circuits. It can input physical quantities such as pressure and liquid level and can be used as a simple RTU.
7. A fault timer is added to the software operation window (located in menu M+9). When the instrument cannot measure normally, the time value will increase.
8. There are up to 8 different language interfaces for customers to choose from.
4. Fixed Ultrasonic Flow Meter Technical Parameters
project | Performance and parameters | |
Host | Accuracy | 1.0% |
Repeatability | 0.2% | |
Maximum flow rate | 6m/s | |
Measuring cycle | 500ms (2 times per second, 128 sets of data are collected in each cycle) | |
Measuring principle | Ultrasonic time difference principle, 4-byte IEEE754 floating point operation | |
Display Interface | Can be connected to 2×10 backlit Chinese characters or 2×20 character LCD displays | |
operate | External 16-key touch keyboard and PC computer parameter setting software | |
enter | 3 optional 4~20mA inputs with an accuracy of 0.1%. Pressure, liquid level, temperature and other signals can be input and can also be used as a digital interface. | |
Two three-wire PT100 platinum resistance input circuits can realize heat measurement function (enthalpy difference method) | ||
Output | Current signal (optional module): 4~20mA, impedance 600Ω floating, accuracy 0.1%. Frequency signal (optional module): Optional between 1~9999Hz, OCT output. Pulse signal: positive, negative, net flow and heat accumulation pulses, dual-channel OCT output (one of which has a programmable pulse width between 6 and 1000mF, the default is 200mF). Alarm signal: Dual-channel OCT output, with nearly 20 source signals to choose from. Data interface: isolated RF485 serial interface. | |
Communication Protocol | MODBUS protocol, MBUS protocol, FUJI extended protocol (compatible with Huizhong flowmeter and water meter communication protocol), it is recommended to use MODBUF-RTU protocol or MODBUS-ASCII protocol | |
Other features | Automatically memorize the accumulated flow and working status of the previous 64 days, the previous 32 months, and the previous 2 years; automatically memorize the previous 16 power-on and power-off times and flow rates, and can realize automatic or manual replenishment; Programmable quantitative controller (can be started using external input signal or MODBUF instruction); 1 bidirectional serial interface can connect multiple external devices such as 4~20mA, data logger, etc.; The working parameters can be solidified into the FLAFH memory inside the machine and automatically called out when powered on; Users can upgrade the software via code files sent via E-mail Fault self-diagnosis function. Fault time timer. | |
Working current | 50mA (without keyboard display and buzzer) | |
Standby current | Using CR2032, data can be kept for 100,000 hours without loss under 24VDC power failure condition | |
Ambient temperature | -10℃~70℃ (Please contact the manufacturer if the temperature is higher than this range) | |
Working hours | continuous | |
sensor | External clamp | M2 is suitable for pipe diameters DN50~700mm |
Signal Cable | Special purpose, factory standard 5 meters, single cable can be extended to 500 meters in certain occasions (not recommended). | |
Protection level | IP68 (can work in water) | |
Measurable pipeline | Pipe | All dense pipes such as steel, stainless steel, cast iron, PVC, PE, PPR copper, aluminum, cement pipes, etc. are allowed to have lining (plastics should try to control the wall thickness to less than 8mm, otherwise it will not be able to be measured if it is not dense). |
Lining material | Epoxy bitumen, rubber, mortar, polypropylene, polystyrene, polyester, polyethylene, hard rubber, bakelite, polytetrafluoroethylene. | |
Straight pipe length | Upstream ≧10D, downstream ≧5D, and distance from pump outlet ≧30D. | |
Measurable pipeline | type | Water |
Turbidity | ≦20000ppm, good effect in sewage measurement, most sewage pipes can be measured stably. | |
temperature | -40℃~160℃ | |
Flow direction | The forward and reverse flows can be measured separately, and the net flow can also be measured. |
Automatic weather station is a modern means of meteorological observation using IOT sensor technology as well as wireless transmission technology to collect, process and analyze meteorological elements, which is of great importance in social production. Due to its small size, low power consumption a...
The establishment and utilization of the Tube Soil Moisture Station provides managers with a powerful tool to monitor and control soil moisture more effectively, promotes water-saving agriculture, and improves management techniques for agricultural production.Closely integrated with local agricultur...
What are the roles of meteorological environment monitors? In real life, people's demand for meteorological services is increasing, and there is a keen need for more accurate and timely access to all kinds of weather information. Therefore, meteorological environment detectors have gained wide a...
With the popularization of transportation, vehicle safety has gradually become a focus of social concern. Low visibility is one of the main causes of road traffic accidents. In order to improve driving safety, vehicle-mounted mobile visibility meters have come into being. In this article, we will el...