Model:FT-WMSM
Brand:fengtu
1.Micro water quality monitor product introduction:
Micro water quality monitor collects water samples through the sampling system, analyzes the water samples, and obtains each index of water quality.In response to the country's strategic policies on strengthening environmental protection, maintaining natural ecological balance, and promoting sustainable development of the national economy, and based on market needs, our company independently developed and produced the outdoor small-scale automatic water quality monitoring station FT-WMSM, which combines the methods specified in the national standard with advanced computer technology to achieve full automation of the measurement process. It can be widely used in surface water quality monitoring of rivers, lakes, etc.
The factors that cause eutrophication of surface water are mainly chemical factors such as N, P, organic matter, HN4- and other chemical factors in the water body. Therefore, monitoring chemical indicators such as total phosphorus, total nitrogen, ammonia nitrogen, chemical oxygen demand, and permanganate index in surface water has become a necessary task. It is necessary to monitor the five conventional parameters (dissolved oxygen, turbidity, conductivity, temperature, and pH) simultaneously to comprehensively reflect the water environment indicators.
2. Micro water quality monitor monitoring principle:
This outdoor water station adopts an integrated design principle, including a water collection and distribution system, a detection unit (five measurement modules for total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and five conventional parameters), a quality control unit, and an auxiliary unit (waste liquid collection, lightning protection, air conditioning, etc.). The core unit is the detection unit, and the total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, and ammonia nitrogen strictly follow the chemical analysis methods specified in the national standard. The conventional five-parameter indicators (dissolved oxygen, conductivity, turbidity, temperature, and pH) are measured using a multi-electrode integrated method.
3. Main specifications and standards for Micro water quality monitor:
According to the design documents, equipment, materials and construction must meet the requirements of the current engineering construction standards and specifications of the People's Republic of China and provinces, autonomous regions, municipalities directly under the Central Government or industries. The technical standards and specifications followed by this project are as follows:
(1) Technical Specifications for Monitoring Total Amount of Water Pollutant Discharge
(2) "Water and Wastewater Monitoring and Analysis Methods" (4th Edition)
(3) "Environmental Water Quality Monitoring Quality Assurance Manual"
(4) Technical Specifications for Surface Water and Wastewater Monitoring (HJ/T91-2002)
(5) Technical Guidelines for River Water Quality Sampling (HJ/T52-1999)
(6) "Technical Requirements for Automatic Chemical Oxygen Demand Water Quality Analyzer" (HJ/T377-2007)
(7) "Technical Requirements for Automatic Permanganate Index Water Quality Analyzer" (HJ/T100-2003)
(8) "Technical Requirements for Automatic Ammonia Nitrogen Water Quality Analyzer" (HJ/T101-2003)
(9) Technical Requirements for Automatic Total Nitrogen Water Quality Analyzer (HJ/T 102-2003)
(10) Technical Requirements for Automatic Total Phosphorus Water Quality Analyzer (HJ/T 103-2003)
(11) Technical Requirements for pH Water Quality Automatic Analyzer (HJ/T96-2003)
(12) "Technical Requirements for Automatic Conductivity Water Quality Analyzer" (HJ/T97-2003)
(13) Technical Requirements for Turbidity Water Quality Automatic Analyzer (HJ/T98-2003)
(14) Technical Requirements for Automatic Dissolved Oxygen (DO) Water Quality Analyzer (HJ/T99-2003)
(15) Relevant national and industry standards and specifications
(16) Environmental Protection Industry Standard of the People’s Republic of China (HJ/T98-2003)
(17) Code for Design of Lightning Protection for Buildings
(18) Design Specifications for Power Supply and Distribution Systems
4. Micro water quality monitor product features:
1. Adopt integrated automatic water quality monitoring station, which can measure multiple elements at the same time;
2. Multiple analysis and detection units with low detection limit, meeting the requirements for online monitoring of surface water;
3. The water collection and distribution unit has the functions of water sample pretreatment and backwashing, with low failure rate and easy maintenance;
4. Optional UPS uninterruptible power supply to ensure that the water station completes the cleaning process in the event of a power outage;
5. Optional video surveillance equipment with real-time remote monitoring function to achieve all-round monitoring;
6. Small footprint, the whole machine footprint ≤ 2m2;
7. Equipped with waste liquid separation and waste liquid collection unit,
8. Meet the collection of waste liquid for more than two weeks; equipped with lightning protection unit to ensure stable and reliable operation of the system;
9. Intelligent constant temperature system, equipped with cabinet-type heating and cooling air conditioners, ensures that the water station operates at the specified working temperature.
5. Micro water quality monitor technical parameters:
project | Total phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, permanganate index parameter performance indicators | ||||
Total Phosphorus | Ammonia nitrogen | Total Nitrogen | Chemical oxygen demand | Permanganate Index | |
Reference Standards | GB11893-89 | HJ/536-2009 | HJ 636-2012 | HJ828-2017 | GB11892-89 |
Measuring range | 0.02~2mg/L (expandable) | 0.1~5mg/L (expandable) | 0.1~10mg/L (expandable) | 15~2000mg/L (expandable) | 0.5~20mg/L (expandable) |
Detection limit | ≦0.01mg/L | ≦0.10mg/L | ≦0.1mg/L | ≦15mg/L | ≦0.1mg/L |
drift | ±5% | ±5% | ±5% | ±5% | ≦0.5mg/L |
Precision | ≤5% | ≤5% | ≤5% | ≤5% | ±5% |
Indication error | ±5% | ±5% | ±5% | ±5% | ≤5% |
Voltage influence | ±10% | ±5% | ±10% | ±5% | ±5% |
Temperature Effect | ±5% | ±5% | ±5% | ±5% | ±5% |
consistency | ≥90% | ≥90% | ≥90% | ≥90% | ±5% |
Sampling period | Time interval (20 to 9999 minutes, adjustable) and hourly measurement mode | ||||
Calibration cycle | 1 to 99 days, any interval, any time, adjustable | ||||
Maintenance cycle | Usually once a month, about 60 minutes each time |
Micro water quality monitor conventional five parameter technical indicators:
Five parameter performance indicators | |||||
Measurement method | pH | Dissolved oxygen | Conductivity | Turbidity | temperature |
Glass electrode method | Fluorescence quenching method | Four-wire electrode method | 90 degree scattered light method | Thermal resistance electrode method | |
Reference Standards | GB/T6920-86 | GB/T11913-89 | GB/T6908-201 | GB/T13200-91 | GB/T13195-91 |
Measuring range | 0~14 | 0mg/L~20mg/L | 0ms/m~500ms/m | 0NTU~1000NTU | 0~50℃ |
drift | ±0.1pH | ±0.3mg/L | ±1% | ±5% | —— |
Precision | ≤0.1pH | ≤5% | ≤1% | ≤5% | —— |
Indication error | ±0.1pH | ≤5% | ±1% | ±5% | —— |
Voltage influence | ±0.1pH | ≤0.3mg/L | ±1% | ±5% | —— |
Temperature compensation accuracy | ±0.1pH | ±0.3mg/L | ±1% | —— | —— |
Water temperature error | —— | —— | —— | —— | ±0.2℃ |
Calibration cycle | Usually twice a month | ||||
Maintenance cycle | Usually once a month, about 30 minutes each time |
Micro water quality monitor machine parameters:
Machine parameters | |
Control unit | ARM9 Embedded Industrial Control System |
Display unit | 15-inch color touch screen control |
Temperature control system | Equipped with dual-purpose air conditioning |
UPS voltage stabilized power supply (optional) | UPS uninterruptible power supply is optional, which can complete the measurement and cleaning process in the event of a sudden power outage |
Lightning protection unit | Lightning protection capability |
Power Requirements | AC 220V±22V, 50Hz±0.5Hz |
Communication interface | 2-way RS485, support 4G wireless transmission |
Machine power | ≦2500W (including external pump, air conditioning powermaximum power during operation) |
Ambient temperature | (5~40)℃ |
Dimensions | Height 1900mm×Width 1480mm×Depth 960mm |
Water station weight | 300kg |
6. Micro water quality monitor configuration list
Serial number | Product Name | quantity |
1 | Stainless steel outdoor cabinet (including air conditioning) | 1 set |
2 | Electrical unit (PLC, relay, circuit breaker, switching power supply, lightning protection) | 1 unit |
3 | Display unit (including 15-inch large screen, microcomputer control program) | 1 set |
4 | Water sampling unit (pipe, sampling pump, float) | 1 set |
5 | Water distribution unit (electric ball valve, pipe) | 1 set |
6 | Pre-treatment unit (flow cell, level sensor, pressure sensor) | 1 set |
7 | Permanganate Index | 1 unit |
8 | COD online monitor (optional) | 1 unit |
9 | NH3N online monitor | 1 unit |
10 | TP online monitor | 1 unit |
11 | TN online monitor | 1 unit |
12 | Five parameters (oxygen solution, conductivity, turbidity, temperature, pH) | 1 unit |
13 | Data acquisition instrument | 1 unit |
14 | Chemical reagents (240 times/month) free of charge | 1 set |
In the wave of smart agriculture, the demand for agricultural smart sensors is rising rapidly, and smart sensors made in China urgently need to accelerate development to meet this market demand. The healthy growth of crops is closely linked to environmental factors such as temperature, humidity and...
The operation of highways is significantly affected by meteorological conditions, and inclement weather such as fog, snowstorms, typhoons and heavy rains can pose a greater threat to driving safety. Under these conditions, the passage of highways may be obstructed or even closed, seriously affecting...
non contact level sensor uses pulse radar for liquids to accurately record levels in liquid media reliably and accurately....
The pH value of water is extremely crucial in both ecology and human activities. In ecological terms, it directly affects the survival and reproduction of aquatic organisms. A suitable pH environment is the basis for aquatic organisms to carry out normal physiological activities. Unsuitable pH will...