Model:FT-ZS07
Brand:fengtu
1. Multi-parameters Water Quality Analyzer Product Introduction
Multi-parameters Water Quality Analyzer is a universal multi-parameter online monitoring instrument, which can display the measured value and sensor status in real time.Online Multi-parameters Water Quality AnalyzerZS07 is an instrument that can measure multiple water quality parameters simultaneously. It integrates multiple sensors and measurement module communication storage, and can quickly and accurately record multiple key parameters in the water body. Including but not limited to water temperature, conductivity, PH, dissolved oxygen, ammonia nitrogen, COD, turbidity, etc., can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to freely communicate with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Multi-parameters Water Quality Analyzer
ZS07 Online Multi-parameters Water Quality Analyzer is widely used in monitoring and controlling various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Multi-parameters Water Quality Analyzer
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Technical Parameters of Multi-parameters Water Quality Analyzer
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V/1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Multi-parameters Water Quality Analyzer Product Dimensions
6. Multi-parameters Water Quality Analyzer Sensor Configuration (Optional)
Serial number | name | Measuring range | Measuring principle | Measurement accuracy | Is it standard? | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ✔ | |
5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | Low turbidity can be customized | |
0~1000NTU (medium turbidity) | Scattered light method | ± 1% | Medium turbidity can be customized | |||
0~3000NTU (high turbidity) | Scattered light method | ± 1% | ✔ | Default | ||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ✔ | |
7 | Ammonia nitrogen | 0~100mg/l | Ion Selective Electrode Method | ±1mg | ✔ | |
8 | cod | 0~500mg/L | UV254 absorption method | ±5% | ✔ | Equipped with an automatic cleaner to prevent biological attachment and avoid light window pollution to ensure long-term monitoring stability; the automatic cleaning time and cleaning frequency can be set, power consumption is 0.7W |
9 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
10 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | Equipped with an automatic cleaner to prevent biological attachment and avoid light window pollution to ensure long-term monitoring stability; the automatic cleaning time and cleaning frequency can be set, power consumption is 0.7W |
atmospheric pressure of air is the force exerted per unit area by the body of air above a specified area (called a column of air), which can be understood as the force exerted by air molecules on a unit area of the Earth's surface....
Measuring rainfall is an important task in fields such as meteorological research, disaster early warning, hydrological monitoring, and agricultural management. Here are three common types of rain gauges.1. Radar Precipitation Sensor Rain Gauge DistrometerThe Radar Precipitation Sensor Rain Gauge Di...
weather instruments can be used to measure the weather, allowing you to monitor wind speed, direction, temperature, pressure, humidity and many other meteorological elements....
The Continuously Operating Reference Station Network (CORS), as a crucial support for modern positioning services, consists of core elements such as continuously operating reference stations, a data center, and a data communication network, forming an organic whole.The continuously operating referen...