1.Doppler Ultrasonic Flow Meter Product Overview
Doppler Ultrasonic Flow Meter is an instrument that can monitor velocity and discharge at the same time. It is suitable for contact flow measurement in open channels and natural rivers.Doppler Ultrasonic Flow Meter (hereinafter referred to as the product) is a new generation of Doppler flowmeter developed by our company based on ultrasonic Doppler, spectrum analysis and low power consumption technology. The product consists of flow velocity measurement module, liquid level measurement module, temperature measurement module, microcontroller, communication module, power supply module, etc., integrating the measurement, storage and communication of flow velocity, liquid level, temperature and flow. It is suitable for flow velocity and flow measurement of open channels, rivers, drainage pipe networks, and various full and part-full pipes.
2. Working Principle of Doppler Ultrasonic Flow Meter
Product flow rate measurement is based on the Doppler effect. The probe emits a beam of ultrasonic waves obliquely upward. When the ultrasonic wave contacts impurities or bubbles in the fluid, the reflected ultrasonic wave will produce a Doppler frequency shift Δf. The Doppler frequency shift Δf is proportional to the fluid flow rate. By measuring the Doppler frequency shift Δf, the flow rate V of the fluid can be measured.
The product measures liquid level based on a pressure sensor. The fluid cross-sectional area S can be automatically calculated through the set channel parameters. Based on the velocity-area method, the liquid flow rate Q can be measured.
Q = V × S
Features
lUsing ultrasonic Doppler principle to measure flow velocity and measurement, with high accuracy and small environmental restrictions;
l The velocity area method is used to measure flow, which does not require the construction of weirs and has low construction costs;
l High integration, supporting simultaneous measurement of flow rate, liquid level, instantaneous flow, cumulative flow and temperature;
lEquipped with temperature sensor to compensate for the influence of water temperature on sound velocity;
l Built-in circular, rectangular, trapezoidal, triangular and other pipeline models, convenient for debugging;
lBionic appearance design effectively reduces garbage occlusion;
lLow power consumption design; operating current is less than 25mA; suitable for battery or solar power supply.
3. Doppler Ultrasonic Flow Meter Parameters
Flow rate range | 0.02m/s~5m/s |
Flow rate accuracy | ±1%FS |
Flow rate resolution | 0.001m/s |
Liquid level range | 0~10m |
Liquid level accuracy | ±0.5%FS |
Liquid level resolution | 0.001m |
Flow range | 0.001~9999999999m³/h |
Flow accuracy | ±3% (depending on the cross-section shape) |
Flow resolution | 0.001m³/h |
Water temperature range | -20℃~60℃ |
Water temperature accuracy | ±0.5℃ |
Water temperature resolution | 0.1℃ |
Operating Voltage | DC 9~28V |
Power consumption | <25mA |
Digital Output | RS-485, Modbus RTU |
size | 182*70*30mm |
Material | ABS |
Protection level | IP68 |
cable length | Standard 10m, can be customized according to needs |
4. How to use Doppler Ultrasonic Flow Meter
1. Installation requirements
Water quality requirements: According to the measurement principle, the water to be tested must contain certain tiny impurities or bubbles, but there should not be too much floating objects in the water to avoid interference.
Water flow requirements: It should be installed downstream of a straight section with a fixed cross-section. The length of the straight section should preferably be 5-10 times the hydraulic radius of the channel (the longer the straight section, the higher the measurement accuracy). There should be no flow obstacles (such as sluices, weirs, etc.) within this distance to ensure the uniformity and stability of the water flow in front of the probe.
2. Installation diagram
3. Installation Case
4. Daily maintenance
In order to keep the instrument working properly, please ask maintenance personnel to maintain the instrument regularly.
The two circular ultrasonic transceivers at the front of the sensor should be protected from impact or scratches by hard objects. If there are foreign objects attached to them, they should be rinsed with clean water or gently scrubbed with a soft cloth.
The pressure sensor at the bottom is located in the mesh water-permeable hole. Its pressure membrane is very thin and must not be touched by hard objects. The instrument should also be protected when it is out of water and not in use. Any foreign matter attached around the water-permeable hole should be carefully removed.
5. Questions and Answers
Problem Description | Check content |
Communication Error | Check whether the electrical connection is normal |
Check whether the communication parameters and communication address are normal. | |
Abnormal flow rate measurement | Check whether the ultrasonic probe is blocked by garbage |
Check if the liquid level is above the sensor | |
Check whether the installation location is in a steady state of water flow | |
The liquid level measurement value is abnormal | Check if the liquid level is above the sensor |
Check if the level probe is blocked | |
Check whether the installation height is set correctly | |
Abnormal flow measurement value | Check whether the channel parameters are set correctly |
The automatic agricultural weather station is capable of automatic sensing, monitoring, warning and analysis of weather, moisture, soil and crop growth, and is so systematic that it achieves intelligent seedling, precision sowing, precision fertilisation, precision irrigation, precision spraying and...
Explosion-proof automatic weather station, mainly used for environmental monitoring and management in electric power, petroleum, chemical and other industries, is a meteorological observation instrument. It can monitor the changes of various meteorological data in the atmosphere exactly within a cer...
Radar water level monitoring station manufacturer - Windway Technology, a domestic manufacturer of radar water level monitoring station, can choose the right products according to different engineering needs in order to meet the needs of different areas of water level observation accuracy and reliab...
The working principle of high frequency radar level meter:FM continuous wave radar level meter general principle is the radar to the top of the tank radiation electromagnetic waves, electromagnetic waves encountered in the medium when the reflection by the radar to receive, send and receive signals...