Model:FT-CW16
Brand:fengtu
Basic structure of fluorescence quantitative PCR instrument
fluorescence quantitative PCR instrument can be flexibly placed in scenarios requiring space, such as biosafety cabinets, quick detection boxes, mobile laboratories, and laboratory countertops.The fluorescence quantitative PCR instrument is an instrument for real-time detection of reactions. It mainly consists of a gene amplification thermal cycle system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: thermal circulation system and fluorescence real-time detection system. The working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument. It uses semiconductor heating and cooling to complete the thermal cycle process. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
fluorescence quantitative PCR instrument technical specifications
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
Indicator name | CW16H | CW32H | CW48H | |
Appearance | ||||
Overall dimensions | 235mm*385mm*175mm (width*depth*height) | |||
weight | 5.6kg | 5.7kg | 5.8Kg | |
Electrical parameters | ~220V/50Hz, 255W | |||
Data interface | USB 2.0 *2 (two on the right) | |||
Environmental parameters | ||||
Operating conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
Shipping and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
altitude | <2500 meters | |||
Noise level | A-weighted, <60dB | |||
Sample parameters | ||||
sample size | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
Test tube type | Single tube, eight row test tubes | |||
sample volume | 15-100uL | |||
Temperature characteristics | ||||
Heating/cooling method | Semiconductor heating/cooling | |||
temperature range | 4℃-99℃ | |||
Maximum heating rate | ≥3.5℃/s | |||
average heating rate | ≥2.5℃/s | |||
Maximum cooling rate | ≥3.5℃/s | |||
average cooling rate | ≥2.5℃/s | |||
Temperature control accuracy | ≤±0.01℃ | |||
Temperature accuracy | ≤±0.1℃ | |||
temperature uniformity | ≤±0.3℃ | |||
Optical properties | ||||
Number of fluorescence detection channels | 4 channels | |||
Light emitting device | High brightness LED | |||
lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
Adapter probe or dye | First channel: 470/520 FAM, SYBR Green | |||
Second channel: 530/570 HEX, JOE, VIC | ||||
Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
Fourth channel: 630/670 CY5 | ||||
Detection sensitivity | 1 copy | |||
Linear detection range | 100~1010 copies | |||
linear correlation coefficient | ≥0.999 | |||
Channel crosstalk | No crosstalk | |||
Test repeatability | ≤1.0% |
Main application fields of fluorescence quantitative PCR instrument
Foodborne pathogen testing
food safety
Animal and plant origin testing
Plant Science and Agricultural Biotechnology
Gene mutations and polymorphisms
animal diseases
basic scientific research
water body monitoring
Pathogen nucleic acid detection
GMO testing
Animal epidemic surveillance
Food hygiene and quarantine
Customs import and export quarantine
An anemometer is a tool used to measure wind speed and direction. There are several ways to measure wind, but there are three main types. It is crucial to pick the right anemometer for your needs.A three-cup anemometer is an instrument that consists of two parts: a wind vane and an anemometer. This...
Ultrasonic wind speed sensor is an instrument for measuring wind speed, which uses the propagation and reflection of ultrasonic waves to measure the speed of wind. This sensor is widely used in wind energy, meteorology, air flow measurement, and other scientific experiments. In the following article...
gas sensor detects a specific gas and measures its content in the air. A gas sensor is a device that detects the presence or concentration of a gas in the atmosphere....
Smart streetlights need all-in-one environmental sensorsWhat are smart streetlights?Intelligent street lights use advanced technology to achieve remote centralised control, adjusting brightness according to traffic flow, remote control of lighting, automatic alarm, anti-theft and remote meter readin...