Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-SZCY
Brand:fengtu
1.Automatic Water Sampler Implementation Standards:
Automatic Water Sampler is a multifunctional sewage sampling instrument that integrates automatic collection and subassembly of sewage.
HJ/T372-2007 Technical Requirements and Testing Methods for Automatic Water Samplers
HJ 493-2009 "Preservation and management technology of water quality samples"
HJ/91.1-2019 Technical Specifications for Wastewater Monitoring
HJ/353-2019 Technical Specifications for Installation of Online Monitoring Systems for Water Pollution Sources (CODcr, NH3-N, etc.)
2. Scope of application of Automatic Water Sampler:
This product can realize single sampling or continuous mixed sampling of sewage at the discharge port, and provide the mixed sample for analysis by online analysis equipment to realize the monitoring function of mixed sewage samples at the discharge port; at the same time, the product has the function of automatic emptying of remote sampling bottles.
3. Main features of Automatic Water Sampler:
1. A/B double barrel configuration: Equipped with A/B double barrels, it can realize continuous mixed sample collection, instrument sample supply, sample retention for exceeding the standard, and automatic emptying of sampling bottles;
2. Automatic emptying function: Different from the "pipeline + electric valve" emptying method, this product adopts the "automatic turntable + lifting mechanism" emptying method, which has the advantages of simple pipeline, compact structure, few fault points, and a large number of sampling bottles (24 bottles);
3. Remote emptying mode: remote single-bottle and multi-bottle emptying functions can be realized through the monitoring platform;
4. Automatic addition of preservatives: It can support the automatic addition of 3 different preservatives to ensure the representativeness of the sample;
5. Security function: Support electronic access control management function, the system automatically generates passwords, records and uploads corresponding information;
6. Real-time network communication interfaces RS232 and RS485 to realize remote sampling setting, execution and response functions;
7. The sampling bottle chamber has a large volume and the temperature is kept constant at 4±2℃ all year round;
8. The sampling structure is designed tightly, and the pipeline has a backflush design, with no sewage residue, ensuring that the sample is pollution-free and authentic;
9. Separation of water and electricity is implemented, and the control part is completely separated from the mechanical water intake part, which improves the safety and stability of the instrument;
10. Parallel sample function: The product can realize the parallel sample collection function and provide double samples for enterprises and regulatory agencies.
11. Equipped with a manual comparison sampling port for mixed water samples.
12. It has the function of collecting instant water samples.
4. Automatic Water Sampler Technical Specifications
Main parameters | Parameter range | Main parameters | Parameter range | |||
Sampling volume | 1~2000mL | Sampling bucket volume | A barrel: 5L | |||
Sampling accuracy | Better than ±5% | Bucket B: 5L | ||||
Sampling bottle sampling volume | 1~1000mL (customizable) | Bottling method | Single sampling, mixed sampling | |||
Proportional sampling error | Better than ±5% | Temperature control error in the chassis | ±2℃ | |||
Clock control error | Δ1≤0.1 and Δ12≤30s | Horizontal sampling distance | ≥50m | |||
Vertical lift | ≥9m | Sampling time interval | 1~99h59min | |||
Bottle storage | 1L*24 | Flow measurement range | 0~9999t/h | |||
Flow input signal | 4~20mA | Operating voltage | (220±15%)V.AC | |||
Insulation resistance | >50MΩ | MTBF | >3000h | |||
weight | ≈120kg | Dimensions | 710*620*1520 mm | |||
Sampling method | Real-time sampling, mixed sampling, sample retention for exceeding the standard, timed sampling, proportional sampling, parallel monitoring sample retention | |||||
Fixative type | Dilute sulfuric acid, dilute nitric acid, etc. | Fixative consumption | Dilute sulfuric acid: 0-20 mL; | |||
Dilute nitric acid: 0~20mL |
A tunnel visibility sensor is a device used to measure visibility data in tunnels and is one of the main tools used to monitor and improve traffic safety in road tunnels.Tunnel visibility sensors measure visibility in the air primarily through the use of a laser beam. By measuring the scattering and...
An ultrasonic wind speed and direction meter is a device that uses ultrasonic technology to determine the speed and direction of wind. It can be used in field environments, as well as indoors for inspection and maintenance work on buildings, and for determining meteorological parameters. Its sensor...
Which is the best ultrasonic wind speed and direction meter?From the meteorological aspect, the meteorological monitoring station should always monitor the wind speed and direction, guide people's travel, timely disaster warning. Military, such as the launch of artillery shells, snipers shooting...
Measuring wind direction is important for predicting the weather, guiding aviation and marine navigation, tracking environmental pollution, planning agricultural activities, optimising sporting events and harnessing wind power for electricity generation. Understanding wind direction helps us to bett...